Tuesday, September 8, 2015

Hp array config utility - command line interface

 hpacucli :



 Location on windows 2003 server - DL380 G6 SERVER


Source : http://www.datadisk.co.uk/html_docs/redhat/hpacucli.htm



This document is a quick cheat sheet on how to use the hpacucli utility to add, delete, identify and repair logical and physical disks on the Smart array 5i plus controller, the server that these commands were tested on was a HP DL380 G3 server with a Smart Array 5i plus controller with 6 x 72GB hot swappable disks, the server had Oracle Enterprise Linux (OEL) installed.
After a fresh install of Linux I downloaded the file hpacucli-8.50-6.0.noarch.rpm (5MB), you may want to download the latest version from HP. Then install using the standard rpm command.
I am not going to list all the commands but here are the most common ones I have used thus far, this document may be updated as I use the utility more.
Utility Keyword abbreviations
Abbreviations chassisname = ch
controller = ctrl
logicaldrive = ld
physicaldrive = pd
drivewritecache = dwc
hpacucli utility
hpacucli # hpacucli

# hpacucli help

Note: you can use the hpacucli command in a script
Controller Commands
Display (detailed) hpacucli> ctrl all show config
hpacucli> ctrl all show config detail
Status hpacucli> ctrl all show status
Cache hpacucli> ctrl slot=0 modify dwc=disable
hpacucli> ctrl slot=0 modify dwc=enable
Rescan hpacucli> rescan

Note: detects newly added devices since the last rescan
Physical Drive Commands
Display (detailed) hpacucli> ctrl slot=0 pd all show
hpacucli> ctrl slot=0 pd 2:3 show detail

Note: you can obtain the slot number by displaying the controller configuration (see above)
Status hpacucli> ctrl slot=0 pd all show status
hpacucli> ctrl slot=0 pd 2:3 show status


Erase hpacucli> ctrl slot=0 pd 2:3 modify erase
Blink disk LED hpacucli> ctrl slot=0 pd 2:3 modify led=on
hpacucli> ctrl slot=0 pd 2:3 modify led=off
Logical Drive Commands
Display (detailed) hpacucli> ctrl slot=0 ld all show [detail]
hpacucli> ctrl slot=0 ld 4 show [detail]
Status hpacucli> ctrl slot=0 ld all show status
hpacucli> ctrl slot=0 ld 4 show status
Blink disk LED hpacucli> ctrl slot=0 ld 4 modify led=on
hpacucli> ctrl slot=0 ld 4 modify led=off
re-enabling failed drive hpacucli> ctrl slot=0 ld 4 modify reenable forced
Create # logical drive - one disk
hpacucli> ctrl slot=0 create type=ld drives=1:12 raid=0

# logical drive - mirrored
hpacucli> ctrl slot=0 create type=ld drives=1:13,1:14 size=300 raid=1

# logical drive - raid 5
hpacucli> ctrl slot=0 create type=ld drives=1:13,1:14,1:15,1:16,1:17 raid=5

Note:
drives - specific drives, all drives or unassigned drives
size - size of the logical drive in MB
raid - type of raid 0, 1 , 1+0 and 5
Remove hpacucli> ctrl slot=0 ld 4 delete
Expanding hpacucli> ctrl slot=0 ld 4 add drives=2:3
Extending hpacucli> ctrl slot=0 ld 4 modify size=500 forced
Spare hpacucli> ctrl slot=0 array all add spares=1:5,1:7       

No comments:

Post a Comment